This README file contains the latest information about installing IBM TotalStorage(tm) FAStT Storage Manager version 8.4 for HP-UX. Refer to the IBM TotalStorage(tm) Support Web Site or CD for the installation and support guide. Last Update: 12/18/2003 Products Supported: --------------------------------------------------- | | Machine Type | Model | |-----------|--------------|------------------------| | FAStT 900 | 1742 | 90X , 90U | |-----------|--------------|------------------------| | FAStT 600 | 1722 | 60U , 60X | |-----------|--------------|------------------------| | FAStT 700 | 1742 | 1RX , 1RU | |-----------|--------------|------------------------| | FAStT 500 | 3552 | 1RX , 1RU | |-----------|--------------|------------------------| | FAStT 200 | 3542 | 1RX , 1RU ,2RX and 2RU | --------------------------------------------------- CONTENTS -------- 1.0 Overview 2.0 Change History 3.0 Installation and Setup Instructions 4.0 Configuration Information 5.0 Unattended Mode 6.0 Web Sites and Support Phone Number 7.0 Trademarks and Notices 8.0 Disclaimer ======================================================================= 1.0 Overview -------------- 1.1 Overview -------------- This IBM Storage Manager release includes the IBM FAStT Storage Manager version 8.4x for HP-UX. The HP-UX and Docs CD-ROM directories contain the documentation and files necessary for installing the IBM FAStT Storage Manager Software version 8.4x for HP-UX. In addition it includes the controller firmware version 05.40.xx.xx and latest NVSRAM for IBM Machine types 1742-900, 1742,1722, 3552 and 3542. HP-UX host attachment to the 1722 (FAStT600) and the 1742-90U/90X (FAStT900) requires the additional purchase of an IBM FAStT900/FAStT600 Host Kit Option. The IBM HP-UX Host Kit options contain the required IBM licensing to attach a HP-UX Host System to the FAStT900 or FAStT600. Please contact your IBM service representative or IBM resellers for purchasing information. The HP-UX CD-ROM directory contains the documentation files necessary for installing the IBM FAStT Storage Manager Version 8.4x. The "IBM TotalStorge Manager Version 8.4: Installation and Support Guide for AIX, HP-UX and Solaris (GC26-7521-03) is also available on IBM's Support Website as a downloadable Portable Document format (PDF) file. Refer to the IBM Support Web Site for latest Firmware and NVSRAM files for IBM machine types 1742, 3542 and 3552 if you are at firmware version 05.00.xx.xx and 05.2x.xx.xx. ======================================================================= 1.2 Limitations ---------------- 1. If you are upgrading controller firmware in IBM FAStT500 storage controller with 512MB Cache, you will have to stop I/O and reboot both controllers before upgrading firmware followed by NVSRAM. You can reboot the controllers either by power cycle the storage subsystem or by pressing the Reset button on both controllers. The Reset button is located on the right of the indicator lights in the opening on the front of each controller unit. To determine Storage Controller cache level, perform the following: a. On a storage management station start the client software and select a storage subsystem. b. Select Tools -> Manage Device to open the Subsystem Management Window. c. Highlight the Storage Subsystem that you are upgrading and then select Storage Subsystem -> Profile. It may take a little time for it to create the Storage Subsystem profile. d. Under the Controllers heading is an entry that displays information similar to the following example: Cache/processor size (MB): 256/32 If this setting is listed as 512/32 you will need to arrange to perform this upgrade procedure at a time that you can stop I/O to the Storage Subsystem in order to ensure a successful firmware download and installation. 2. Storage Manager prompts you for a password if all hard disk drives are removed from the storage subsystem. After removing all drives from a storage subsystem (or not powering on drives and only the controller), the IBM FAStT Storage Manager software will prompt you for a password when trying to start the software or trying to perform protected operations. Any password entered will fail. Password information is stored on a reserved area of each hard disk drive on the storage subsystem. Each drive stores a mirrored copy of the password data. When there are no drives in the storage subsystem, the storage management software does not find the password data when you attempt password protected operations. Add one drive to the storage subsystem and retry the operation. Since the RAID controller unit should not be powered on until the expansion units are attached and powered on, this should be done by powering off the RAID controller unit, properly attaching all expansion units (with drives installed), to the RAID controller unit and powering them on, and then powering the RAID controller unit back on. At this point the storage subsystems can be rediscovered and managed using the IBM FAStT Storage Manager 8.4x software. 3. Display issues when using 256 color settings. A brownish hash pattern is displayed on the windows and in online help when running in 256 color mode. Run the Storage Manager 8 application in a higher display mode. 4. The FAStT Storage Management dialog windows may be displayed cropped without the vertical and horizontal scroll bars. Just move the mouse pointer over the edge of the window until the mouse pointer change to window resize pointer, left click and hold to grip the window edge to resize it. 5. If you get "Error 21 - The Operation cannot complete because a ... is in progress" error when you issue a Subsystem Management command from the IBM FAStT Storage Manager Client, the command may be cached. If the command is cached, the IBM FAStT Storage Manager Client will run the command as soon as the controller resources are available. Wait for at least ten minutes and check to see whether the command has been run. If not, re-attempt the command. 6. If the controller in the IBM FAStT Storage Server with firmware 05.4x.xx.xx is connected to a SAN with more than 64 host connections per controller port that can log into the controllers, one must either use the switch zoning function or rearrange the SAN connections so that only the maximum number of host connections can be seen and log into the controller. The FAStT Storage Subsystem FAStT900, FAStT700 and FAStT500 (IBM machine type 1742 and 3552) have two ports per controller - one per minihub slot. The FAStT Storage FAStT600 (IBM machine type 1722) has two ports per controller. The FAStT storage Subsystem FAStT200 (IBM machine type 3542) has only one port per controller. 7. If you define a large number of arrays, you will not be able to right-click a logical drive and get a pop-up menu in the Physical View of the Subsystem management window. You must use the Logical Drive pull-down menu to select the logical drive options. 8. The IBM FAStT Storage Server hardware and software is designed to have redundant paths from the host system to ensure the availability of storage. However, it is possible to connect a single host adapter from the host system to one of the controller minihubs and then connect this minihub to the minihub of the other controller. This configuration will create a FC-AL loop between the host adapter and the two IBM FAStT Storage Server controllers and no redundant path to the host system. When you connect the two minihubs together, always connect the "IN" port of one minihub to the "OUT" port of the other minihub or vice versa. Do not connect the "IN" port of one to the "IN" port of the other minihub or the "OUT" port of one minihub to the "OUT" port of the other minihub. Please note the following: - Single host bus adapter in a direct-attach configuration with the FAStT600 and FAStT600 Turbo(IBM machine type 1722-60u and 1722-60x)is not a supported configuration at this time. - Single FAStT controller with a single host bus adapter is not a valid configuration for direct-attach or SAN-attach. - Single host bus adapter configuration is supported in a SAN-attache configuration. - MUST use both FAStT controllers when using a single host bus adapter. 9. Host groups can not be created at the default group level. Host groups MUST be created at the storage system level. 10. FAStT, now supports a maximum of a 127 LUNs on HP-UX Version 11.i. However, FAStT only supports 32 LUNs on HP-UX Version 11.0. 11. Use of Flash copy in the HP-UX environment has some limitations while used in a multihost environment. Flashcopy LUN has to be assigned to the same host for smooth operation. If the Flashcopy LUN is assigned to a different host partition from the primary LUN ,the I/O operation will slow down significantly during a failover/failback situation. Therefore, the use of Flashcopy LUN on a different host partition is not recommended at this time. 12. Host groups can not be created at the default group level. Host groups MUST be created at the storage system level. - If you are running a FAStT 600 storage configuration without partitioning enabled, we strongly recommend you use the default host group. This ONLY applies to the FAStT 600. ======================================================================= 1.3 Enhancements ----------------- The following features have been added to FAStT Storage Manager 8.40: - Now supports Solaris 9 - Support for up to 255 LUNs per storage partition for Solaris 7, 8 and 9 with VERITAS Volume Manager - Support for up to 256 LUNs per storage partition for AIX 5.1 and 5.2 ======================================================================= 1.4 Prerequisites ------------------ IBM FAStT Storage Manager version 8.4x for HP-UX was tested heterogeneously on the following HP servers: An HP 9000/800 series server with the following minimum requirements: 1. 440 Mhz PA-RISC or faster. 2. 1 GB Memory or more 3. 0.7MB available on /opt. Root (or root-equivalent) privileges for SMutil and SMagent installation. 4. 2.7MB available disk space on /opt. Root (or root-equivalent) privileges for SM7migrate installation. 5. For installation in a Java Runtime Environment, at least 90 MB available disk space on /opt and at least 140 MB available on /tmp. Ensure your host is running one of the following operating systems. The storage management software installation program will not verify patches. Some patches might be superseded by other patches. Refer to the Operating System documentation or contact your operating system supplier for more information. 3. HP-UX Version 11.0 (64-bit) with the following patches: Warning storage administrators and system administrators, it's imperative you load the exact patches listed below. Deviating to the most recent patches released by Hewett Packard is not recommended. PHKL_23939, version 1.0 : Fibre Channel Mass Storage Driver Patch PHKL-27003, version 1.0 : SCSI IO Cumulative Patch PHKL_24027, version 1.0 : VxFS 3.1 cumulative patch PHKL_27364, version 1.0 : Probe,sysproc,IDDS,PM,VM,PA-8700, asyncio 4. HP-UX Version 11.i (64 bit) with the following patches: Warning storage administrators and system administrators, it's imperative you load the exact patches listed below. Deviating to the most recent patches released by Hewitt Packard is strongly discouraged. PHKL_26519, version 1.0 : SCSI IO Subsystem Cumulative Patch FibrChanl-00,B.11.11.09 : PCI/HSC FibreChannel; Supptd HW= A5158A A6795A PHKL_26743, version 1.0 : LVM Cumulative PHCO_27408, version 1.0 : LVM commands cumulative patch 5. For high availability clusters of HP 9000/Series 800 computers, install the HP MC/ServiceGuard 11.14 software package. ======================================================================= 1.5 Dependencies ----------------- IBM FAStT Storage Manager version 8.4 provides full management support IBM machine types 3552 and 3542 storage controllers that have at least firmware version 04.00.02.xx, IBM Machine type 1742-900 and 1742 storage controllers that have at least firmware version 05.00.04.xx or IBM Machine type 1722 storage controllers that have at least firmware version 05.3x.xx.xx. The only IBM FAStT Storage Manager 8.4 supported management function on controllers with firmware version 04.xx.xx.xx to 04.xx.01.xx is controller firmware and NVSRAM download. ======================================================================= 2.0 Change History ----------------------------- This is the latest release of IBM FAStT Storage Manager version 8.4x for HP-UX. ======================================================================= 2.1 Key Features added to IBM FAStT Storage Manager version 8.4 with controller firmware level 05.3x.xx.xx. See the IBM TotalStorage FAStT Storage Manager version 8.4: Installation and Support Guide for AIX,HP-UX and Solaris ======================================================================= 2.2 Code levels at time of release are as follows ------------------------------------------------- 1. IBM FAStT Storage Manager Client version: 08.40.G5.02 2. IBM FAStT Storage Manager Agent version: 08.40.45.00 3. IBM FAStT Storage Manager Utilities version: 08.40.45.00 4. IBM FAStT Storage Manager Runtime version: 08.40.45.00 Refer to the http://ssddom02.storage.ibm.com/techsup/webnav.nsf/support/disk IBM web page for the latest released code levels. Note: A supported IBM SAN Switch is required when attaching FAStT storage arrays to AIX and non-AIX servers in a Heterogeneous environment. ======================================================================= 3.0 Installation and Setup Instructions ----------------------------------------- 3.1 Step-by-step instructions for this code update are as follows ------------------------------------------------------------------ 1. Install and update the driver for the IBM FAStT Host Adapter. a. Install the hardware by using the instructions that come with the adapter. b. Install the Fibre Channel Host Bus Adapter driver by using the instructions provided with the adapter. 2. Install the new Storage Manager version 8.4x software. Refer to the IBM FAStT Storage Manager version 8.4x for HP-UX Installation and Support Guide for detailed installation instructions. ======================================================================= 3.2 IBM has tested configurations with the following Fibre Channel Host Bus Adapters, device drivers and Storage Controller Firmware: 1. OS: HP-UX 11.0 Vendor: HP, Model: A5158A and A6795A HBA Driver: Bundle A6795A, version B.11.00.10: PCI Tachyon TL/TS/XL2 Fibre Channel 2. OS: HP-UX 11.i Vendor: HP, Model: A5158A and A6795A HBA Driver: Bundle FibrChanl-00, version B.11.11.09: PCI/HSC FibreChannel; Supptd HW=A6684A,A6685A,A5158A,A6795A ======================================================================= 3.3 Helpful Hints ------------------ 1. Fabric topology zoning requirement. To avoid possible problem at the host level, all Fibre Channel Switches must be zoned such that a single host bus adapter can only access one controller per storage array. 2. For partitioning in clusters. The partition must be done on the host group level not on the host level. This will allow all cluster hosts to see the same storage. 3. Interoperability with tape devices is supported on separate HBA and switch zones. 4. Interoperability with Shark and SDD Software is supported on separate HBA and switch zones. 5. Do not delete the Access LUN or Access Volume. The Access LUN is required by the SMclient to communicate with the storage controllers when using the in-band management method. 6. Depending on the storage subsystem that you have purchased, you may have to purchase the FAST storage partitioning premium feature option or an option to upgrade the number of supported partitions in a storage subsystem. Please see IBM Marketing representatives or IBM resellers for more information. - IBM FAStT600 storage subsystem (machine type 1722): The standard configuration does not have the FAST storage partitioning premium enabled. Four partition, eight partition and an upgrade from four to eight partition storage partitioning premium feature options can be purchased. - IBM FAStT200, FAStT500, and FAStT700 storage subsystems (machine type 3542, 3552 and 1742 - models 1RU and 1RX, respectively): The standard configuration has 64 partitions storage partitioning premium option installed. No additional storage partitioning premium feature options can be purchased for these storage subsystems. - IBM FAStT900 storage subsystem (machine type 1742 - models 90X and 90U): The standard configuration has 16 partition storage partitioning premium option installed. An upgrade from 16 to 64 partition storage partitioning premium feature option can be purchased. ======================================================================= 4.0 Configuration Information ----------------------------- 4.1 Configuration Settings -------------------------- 1. By default, the IBM FAStT Storage Manager 8.4 firmware does not automatically map logical drives when the IBM FAStT storage partitioning premium feature is enabled. This means that the logical drives after being created are not automatically presented to the host systems. a. For a new installation, after creating new arrays and logical drives, create a storage partition with the host type of HP-UX and map the logical drives to this partition. b. If you are upgrading the NVSRAM with Storage Partitions and the host system OS was other than Microsoft Windows NT is accessing the default host group, you will need to change the default host type. After upgrading the NVSRAM, the default host type is reset to Windows non-clustered (SP5 or higher). Refer to the IBM FAStT Storage Manager online help to learn more about creating storage partitions and changing host types. 2. When you are configuring IBM machine type 1742, 3542 or 3552 storage controllers as boot devices, contact IBM support for supported configurations and instructions for configuring IBM storage controllers as boot devices. 3. Running script files for specific configurations. Apply the appropriate scripts to your subsystem based on the instructions you have read in the publications or any instructions in the operating system readme file. A description of each script is shown below. - SameWWN.scr: Setup RAID controllers to have the same World Wide Names. The World Wide Names (node) will be the same for each controller pair. The NVSRAM default sets the RAID controllers to have the same World Wide Names. - DifferentWWN.scr: Setup RAID controllers to have different World Wide Names. The World Wide Names (node) will be different for each controller pair. The NVSRAM default sets the RAID controllers to have the same World Wide Names. - EnableDriveMigration.scr: The Enable drive migration script scans the drives for configurations when they are added to a storage system and will also attempt to use configurations found on the newly added drives. The NVSRAM default will enable drive migration. - DisableDriveMigration.scr: The disable drive migration script allows the addition of disk drives while the system is running. in addition, it identifies the drives as unused capacity regardless of past drive configuration. The NVSRAM default will enable drive migration. 4. When you are configuring IBM machine type 1742 or 3552 storage controllers in host cluster Remote Mirror configurations, contact IBM support for supported host cluster configurations and instructions for configuring IBM storage controllers in clustered Remote Mirror configurations. 5. In the event the worldwide port names (WWPNs) do not show up automatically during the initial configuration of your FAStT storage system, please reboot the HP-UX host. ======================================================================= 4.3 Unsupported configurations ------------------------------ The following lists configurations that are currently not being supported with IBM FAStT Storage Manager 8.4x. 1. Fibre Channel loop environments with the IBM Fibre Channel hub, machine type 3523 and 3534, in conjunction with the IBM Fibre Channel switch, machine types 2109-S16, 2109-F16, 2109-S8 or 3534-F08. In this configuration, the hub is connected between the fibre channel switch and the IBM FAStT storage subsystem controller ports. 2. The IBM Fibre Channel hub, machine type 3523, connected to IBM machine type 1742, 3542 and 3552. ======================================================================= 5.0 Unattended Mode --------------------- N/A ======================================================================= 6.0 WEB Sites and Support Phone Number ---------------------------------------- 6.1 IBM TotalStorage™ Disk Storage Systems Technical Support web site: http://www.ibm.com/storage/support/fastt 6.2 IBM TotalStorage(tm) Marketing Web Site: http://www.storage.ibm.com/hardsoft/disk/fastt/index.html 6.3 If you have any questions about this update, or problem applying the update go to the following HelpCenter World Telephone Numbers URL: http://www.ibm.com/planetwide ======================================================================= 7.0 Trademarks and Notices ---------------------------- 7.1 The following terms are trademarks of the IBM Corporation in the United States or other countries or both: IBM TotalStorage(tm) the e-business logo xSeries pSeries HelpCenter Linux is a registered trademark of Linus Torvalds. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United states, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Other company, product, and service names may be trademarks or service marks of others. ======================================================================= 8.0 Disclaimer ---------------- 8.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. 8.2 Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corporation.