Release Notes for ProLiant Support Pack for Microsoft Windows 2000, v7.40 Following is the list of all the components that changed in 7.40 from 7.30. ********************************************** cp005413.exe - HP Insight Management Agents for Windows 2000/Windows Server 2003, v7.40.0.0 Fixes Resolved the following: Issue with the storage box and physical drive SNMP traps. The agent was not provided sufficient location information for drives and storage boxes attached to a Smart Array P600. Issue with the drive hot plug icon on the Smart Array P600. The agent was incorrectly determining this value. Enhancements Added support for the following: NC324i, NC325i, NC326i, NC380T HP 8 INT Port SAS/SATA HBA. MSA1500 Active/Active firmware. Made the 'team member role' to match NCU's text. Added status 'redundancy lost' and 'redundancy reduced' to teams. ********************************************** cp005397.exe - HP ProLiant iLO Advanced and Enhanced System Management Controller Driver for Windows 2000/Server 2003, v5.37.0.0 Fixes Modified to correctly log Windows bugcheck information to the Integrated Management Log (IML). Versions 5.35.0.0 and 5.36.0.0 of this driver did not write the bugcheck information to the IML. Enhancements Added support for new servers. ********************************************** cp005301.exe - HP StorageWorks Fibre Channel Adapter Kit for Emulex SCSIPort Driver for Windows 2000/ Windows Server 2003, v1.3.0.0 Enhancements Initial release. ********************************************** cp005396.exe - Version Control Agent for Windows, v2.1.2.740 Enhancements Updated for ProLiant Support Pack maintenance. ********************************************** cp005625.exe - HP ProLiant CSB-6 ATA-100 IDE RAID Management Utility for Windows 2000/Server 2003, v7.30.32.0 B Enhancements Updated for ProLiant Support Pack maintenance. ********************************************** cp005624.exe - HP ProLiant Integrated ATA RAID Management Utility for Windows, v2.5.32.7 B Enhancements Updated for ProLiant Support Pack maintenance. ********************************************** cp005414.exe - HP Insight Diagnostics Online Edition for Windows 2000/Server 2003, v7.4.0.1570 Enhancements Added Diagnosis feature giving the user the ability to diagnose Smart Array SCSI hard disk drives. Modified the user interface. Added support for new hardware. ********************************************** cp005423.exe - HP ProLiant Legacy Port Configuration Component for Windows 2000, v1.8.2195.0 B Enhancements Updated for ProLiant Support Pack maintenance. ********************************************** cp005464.exe - HP Lights-Out Online Configuration Utility for Windows 2000/Server 2003, v1.2.4.0 Fixes Updated so HPONCFG 1.2 works reliably with Remote Insight Lights-Out Edition II in Microsoft Terminal services with Proliant Support Pack version 7.40 or higher installed on the system. Enhancements Updated HPONCFG 1.2 to allow dynamic variable substitution. XML scripts can contain variables. Values for these variables can be specified as command line argument when executing HPONCFG. This reduces the need to re-write XML scripts with different values for configuration parameters. When HPONCFG 1.2 writes current iLO/RILOE II configuration information to a file, it writes them in RIBCL format. This configuration file can be used directly to restore the iLO/RILOE II configuration. This will help the users to easily store and restore iLO/RILEO II configuration information. ********************************************** cp005465.exe - HP ProLiant Smart Array SAS/SATA Controller Driver for Windows 2000, v5.2.0.32 Enhancements Updated to support the following IOCTLS defined in the CSMI Specification: CC_CSMI_SAS_GET_DRIVER_INFO CC_CSMI_SAS_GET_CNTLR_CONFIG CC_CSMI_SAS_GET_CNTLR_STATUS CC_CSMI_SAS_GET_SCSI_ADDRESS CC_CSMI_SAS_GET_DEVICE_ADDRESS CC_CSMI_SAS_SSP_PASSTHRU: Variable length CDB not supported at this time. Connection rate setting not supported at this time. Additional response data CC_CSMI_SAS_GET_PHY_INFO (SA P600 firmware .26 required) CC_CSMI_SAS_GET_LINK_ERRORS (SA P600 firmware .26 required) CC_CSMI_SAS_GET_SATA_SIGNATURE (SA P600 firmware .26 required) CC_CSMI_SAS_SMP_PASSTHRU (SA P600 firmware .26 required) Updated Version Major Number for SmartStart 7.40. ********************************************** cp005402.exe - HP ProLiant Smart Array 5x and 6x Controller Driver for Windows 2000/Server 2003, v5.68.0.32 Fixes Resolved an issue where the cpqcisse driver does not work with external arrays. Enhancements Updated Version Major Number for SmartStart 7.40. ********************************************** cp005407.exe - HP StorageWorks Fibre Channel Array Notification Driver for Windows 2000/Server 2003, v5.30.0.32 Fixes Resolved an issue wherein the cpqfcac driver shows improper Cabinet Bay Chassis Slot Number information on non cellular systems. Resolved an issue wherein the cpqfcac driver does not log events using the chassis name but the chassis serial number. Enhancements Updated Version Major Number for SmartStart 7.40. ********************************************** cp005403.exe - HP ProLiant Smart Array Device Manager Extension for Windows 2000/Server 2003, v5.10.0.32 Fixes Resolved an issue where the DME could not detect the installed ACU utility. Resolved an issue where the DME had incorrect URL to launch the Storage Agents. Resolved an issue where 'HP Web Agents have not been installed' message is displayed in Tools tab of Smart Array 6i Properties Resolved an issue where the Redundancy tab breaks on Win2K after upgrading from 7.20 to 7.30. Enhancements Updated Version Major Number for SmartStart 7.40. ********************************************** cp005470.exe - HP ProLiant Smart Array SAS/SATA Event Notification Service for Windows 2000/Server 2003, v5.4.0.32 Fixes Modified the power supply events. The HP Proliant Smart Array SAS/SATA Event Notification Service will now accurately report power supply events. ********************************************** cp005393.exe - HP ProLiant Array Configuration Utility for Windows, v7.40.8.0 Fixes Modified tabbing when using the Configuration Wizards to no longer lock the browser. Enhancements Added support for HBA SSP connection name and host mode in scripting capture and replay. Updated so RAID ADG is now referred to as RAID 6 (ADG). ********************************************** cp005394.exe - HP ProLiant Array Diagnostics Utility for Windows, v7.40.7.0 Enhancements Updated so RAID ADG is now referred to as RAID 6 (ADG). ********************************************** cp005395.exe - HP ProLiant Array Configuration Utility (CLI) for Windows, v7.40.7.0 Enhancements Updated so RAID ADG is now referred to as RAID 6 (ADG). ********************************************** cp005368.exe - HP Integrated Tape Applications and Utilities for Windows, v1.0.0.0 Enhancements Initial release. ********************************************** cp005496.exe - HP NC31xx Fast Ethernet NIC Driver for Windows 2000, v8.0.21.0 Enhancements This driver now better negotiates flow control between the NIC and a switch,so fewer frames are dropped due to network traffic congestion. ********************************************** cp005497.exe - HP NC61xx/71xx/310x Gigabit Ethernet NIC Driver for Windows 2000, v8.6.11.0 Enhancements This driver now handles interrupts more efficiently during busy conditions, so it loses fewer interrupts and performs better. ********************************************** cp005318.exe - HP Network Configuration Utility for Windows 2000, v8.10.0.0 Enhancements Added support for the following: NC320i, NC324i, NC325i and NC326i LOMs Read-only web interface accessible through the System Management Homepage. The ability to create a detailed log of your system configuration for submission to third-level technical support personnel. Status of the active path and fast path states, along with member ID information and readability enhancements. Dynamic dual-channel load balancing, so user intervention is minimal and the NIC grouping happens automatically. User-specified preference order for transmit load balancing, so you can select which team member will be primary. Some of these enhancements are available only when you purchase a license for the ProLiant Essentials Intelligent Networking Pack. ********************************************** cp005566.exe - HP NC10xx/67xx/77xx/150x/320x/325x Gigabit Ethernet NIC Driver for Windows 2000, v8.39.1.0 Enhancements This driver now supports the NC320i and NC325i LOMs. ********************************************** cp005474.exe - HP NC370x/371x/373x/380x Multifunction Gigabit Server Adapter Driver for Windows 2000, v2.1.3.0 Enhancements This driver has been updated to provide better performance. ********************************************** cp005556.exe - HP Virus Throttle for Windows 2000, v8.10.0.0 Enhancements This driver now supports the NC320i, NC324i, NC325i, and NC326i LOMs. ********************************************** cp005392.exe - HP ProLiant Integrated Management Log Viewer for Windows, v5.2.0.0 Fixes Corrected display of the 'Loss of memory mirror' message. ********************************************** cp005391.exe - HP ProLiant Remote Monitor Service for Windows, v5.1.2195.0 B Enhancements Updated for ProLiant Support Pack maintenance. ********************************************** cp005409.exe - HP ProLiant Remote Insight Board Driver for Windows 2000/Server 2003, v2.5.0.0 Fixes Resolved possible system lockup when multiple applications attempt to access the driver. Enhancements Improved interface between driver and Insight Management Agents. ********************************************** cp005410.exe - HP ProLiant Integrated Lights-Out Management Interface Driver for Windows 2000/Server 2003, v1.7.2195.0 Enhancements Improved interface between driver and Insight Management Agents. ********************************************** cp005411.exe - HP ProLiant Remote Insight Lights-Out II Board Driver for Windows 2000/Server 2003, v3.4.0.0 Fixes Resolved possible system lockup when multiple applications attempt to access the driver. Enhancements Improved interface between driver and Insight Management Agents. ********************************************** cp005412.exe - HP ProLiant Rack Infrastructure Interface Service for Windows 2000/Server 2003, v1.21.0.0 Enhancements Added support for 1U power enclosure. ********************************************** cp005652.exe - HP StorageWorks Fibre Channel Adapter Kit for QLAxxxx SCSIPort Driver for Windows 2000/Server 2003, v1.4.1.0 Enhancements Initial release. ********************************************** cp005545.exe - HP System Management Homepage for Windows, v2.1.2.127 Enhancements Added log rotation feature under Windows to better manage System Management Homepage logs. Addressed a Cross Site Scripting (XSS) issue in this release. ********************************************** cp005266.exe - HP ProLiant SATA RAID Controller Driver for Windows 2000/Server 2003, v4.2.1.7365 Enhancements Initial release. ********************************************** cp005602.exe - ATI ES1000 and Radeon 7000 Video Controller Driver for Windows 2000/Server 2003, v6.14.10.6553 Enhancements Initial release. ********************************************** Copyright 2003-2005 Hewlett-Packard Development Company, L.P.